TRIGGER_LEVEL_MDO3XXX
The TRIGGER_LEVEL_MDO3XXX node sets the trigger voltage (or queries it).The trigger voltage is the level at which an oscilloscope will find the
start of a signal.
Requires a CONNECTION_MDO3XXX node at the start of the app to connect with
the instrument. The VISA address will then be listed under 'connection'.
This node should also work with compatible Tektronix scopes (untested):
MDO4xxx, MSO4xxx, and DPO4xxx.Params:connection : VisaConnectionThe VISA address (requires the CONNECTION_MDO3XXX node).trigger_volts : floatThe voltage to set the triggering level to.query_set : strWhether to query or set the triggering voltage.Returns:out : DataContainerScalar: The triggering voltage.
Python Code
from flojoy import flojoy, DataContainer, Scalar, VisaConnection
from typing import Optional, Literal
@flojoy(inject_connection=True)
def TRIGGER_LEVEL_MDO3XXX(
connection: VisaConnection,
trigger_volts: float = 0.1,
query_set: Literal["query", "set"] = "query",
default: Optional[DataContainer] = None,
) -> Scalar:
"""The TRIGGER_LEVEL_MDO3XXX node sets the trigger voltage (or queries it).
The trigger voltage is the level at which an oscilloscope will find the
start of a signal.
Requires a CONNECTION_MDO3XXX node at the start of the app to connect with
the instrument. The VISA address will then be listed under 'connection'.
This node should also work with compatible Tektronix scopes (untested):
MDO4xxx, MSO4xxx, and DPO4xxx.
Parameters
----------
connection: VisaConnection
The VISA address (requires the CONNECTION_MDO3XXX node).
trigger_volts: float
The voltage to set the triggering level to.
query_set: str
Whether to query or set the triggering voltage.
Returns
-------
DataContainer
Scalar: The triggering voltage.
"""
tek = connection.get_handle()
match query_set:
case "query":
volts = tek.trigger.level()
c = volts
case "set":
tek.trigger.level(trigger_volts)
c = trigger_volts
return Scalar(c=c)
Example
Having problem with this example app? Join our Discord community and we will help you out!